Testing Variable Resistors of a Virtual Reality Glove
|
Test an interactive glove containing a flex circuit with
resistive load cells on each finger. The glove needs to be
tested in an open and closed fist position...
- more
information |
 |
Guided Assembly of Catheters
|
Help guide the assembly of a medical catheter which has numerous
conductive rings at the end. Each ring needs to be wired to
the correct pin on a connector at the base of the catheter.
This isn't your ordinary second side pinning application...
- more
information |
 |
Testing for Intermittent Connections
|
Customer needed to test for intermittant shorts as fast as possible on
booster rocket seperation cables...
- more
information
|
 |
Hipot Testing a PCB Four-Up
|
Hipot test a printed circuit board. The board is already in
production, being built and continuity tested four-up.
Re-using existing fixturing saves money...
- more
information |
 |
Same Side Shield Testing
|
Make sure wires really are inside a shield. It's possible to miswire
the shield connections so a given pair of conductors are housed in the
wrong shield...
- more
information |
 |
Testing the Breakdown Voltage of Gas Fuses
|
Customer needed to test the breakdown voltage across gas fuses.
- more
information |
 |
Assembly Instruction Prompts
|
Customers requested a method to pass written instructions to the test
person during the testing process.
- more
information |
 |
Version Control of Test Programs
|
This customer requested a method to institute an automated revision
control approach for all his test/wirelist programs.
- more
information |
 |
Testing Thermisters; Compensating for Room Temperature Changes
|
The customer was looking for a inexpensive and simple way to
automatically compensate for room temperature changes while testing
thermisters.
- more
information |
 |
Change Hipot Voltage Per Net
|
This project required a way to test selected portions of an assembly
with various hipot voltages and dwell times while keeping other portions
of the assembly protected from all voltages.
- more
information |
 |
Testing Rotary Switches
|
How to test a medical device containing a rotary switch having 4 poles
with 16 positions per pole. A second selector switch acts as
a pole selector for the first switch.
- more
information |
 |
Testing Data Transformers
|
This custom test dramatically reduced the number of field failures by
making the final assembly test quicker and more robust. As
the defects went down, throughput went up!
- more
information |
Many of these applications use scripting. For more information on
scripting see: Scripting
Language Option for the Touch 1/1100R+/1100H+
For More Information Contact:
Cirris Solutions Ltd
4 Commerce Way, Stanbridge Rd., Leighton Buzzard, LU7 4RW
Tel: 01252-374466
FAX: 01525-374468
Internet: sales@cirris.co.uk
|